86-15728040705

Tabletop Autoclaves

-- Steady & Reliable Manufacturer --

Tabletop autoclaves are compact sterilization units designed for placement on benches or trolleys within clinical environments. These devices offer full steam sterilization functionality in a reduced footprint, enabling clinics and small laboratories to perform validated cycles without a dedicated sterilization room. Control interfaces range from simple mechanical timers to digital touch panels with multiple pre-set programs and cycle monitoring. Design priorities include rapid heat-up, reliable sealing mechanisms, and effective drying to facilitate quick instrument turnover while maintaining operator safety and ease of use.

Specification

ModelChamber VolumeProgramsMax PressurePowerWeight
WR-TT1212L121°C/134°C, Test2.1 bar900W22kg
WR-TT1616L121°C/134°C, Drying2.2 bar1100W26kg
WR-TT2222L121°C/134°C, PreVac2.4 bar1400W31kg

Application

Tabletop autoclaves are widely used in dental clinics, outpatient procedure rooms, tattoo studios, podiatry practices, and small medical research labs where space is constrained. They are suitable for sterilizing sets of instruments, handpieces that tolerate steam sterilization, and small reusable items such as mixing bowls, tweezers, and trays. The units support routine reprocessing tasks between patient appointments and provide flexibility for practices that require reliable sterilization without central sterilization infrastructure. For laboratories, tabletop autoclaves also serve for sterilizing glassware and non-lumened tools used in bench-top procedures.

Payment & Shipping

Standard payment methods include T/T and L/C; small orders may be paid fully in advance or via secure online payment for sample purchases. Shipping is commonly by sea container for bulk orders, with air freight options for expedited deliveries. Tabletop autoclaves are packaged in protective foam and cartons; additional wooden crating is available for higher protection. Export documentation and optional certifications can be included as required for destination country compliance.

Common Questions

  • Q: How much bench space is required?
  • A: Bench space requirements depend on model dimensions but typically allow for 50–100 mm clearance around the unit for ventilation and loading access; check the specific model dimensions before installation.
  • Q: Are tabletop autoclaves suitable for busy clinics?
  • A: Tabletop units are suitable for clinics with moderate throughput; for very high instrument volumes, larger floor-standing sterilizers may be more efficient.
  • Q: What maintenance is recommended?
  • A: Routine water quality checks, chamber cleaning, gasket inspection, and occasional descaling of the steam generator are standard maintenance tasks to ensure consistent performance.
  • Q: Can tabletop units perform vacuum cycles?
  • A: Some advanced tabletop models include pre-vacuum capability for porous and lumened loads; verify model specifications if vacuum cycles are required.
Recommended LINS: Tabletop Dental Autoclaves Dental Autoclaves Pre-Vacuum Autoclaves Large Capacity Lab Autoclaves Vertical Floor Standing Autoclaves Class N Gravity Autoclaves Pure Water Distillers for Autoclaves B-D/Helix Test Autoclaves Hospital Grade Autoclaves

Wanrui Medical Instrument

Our products are mainly exported to over 30 countries such as USA,Germany,Japan,Spain,Italy,UK,Korea,Australia,Canada,Iraq,Algeria and etc. Ningbo Wanrui obtains customer's trust through honesty and sincerity, and redounds on customers by superior quality & high-tech product. We commit our selves to making friends both in China and oversea by our exceptional products and complete service service! "Keep improving, serve our customers" is our goal, we sincerely look forward to cooperating with you!
Please Feel Free To Contact Us

If you have any question for the installation
or need support, please feel free to contact us.

86-15728040705
86-18957491906

86-15728040705
86-18957491906